RADTriage-TLD/OSL

Don’t be a dosimeter, carry RADTriage

RADTriage-TLD (Dual sensor dosimeter)

RADTriage-TLD dual sensor dosimeter card

WHY WE DEVELOPED RADTriage-TLD?

  • RADTriage is needed during the first months of radiological emergency to minimize panic.
  • After a radiological incident governments wants to measure dose of children, pregnant women and people living in affected area to measure the low dose on routine basis (e.g., every month or three months) and calm the public that they are not exposed to high dose, e.g., with RADTriage. (Fukushima area needed these type of dosimeters but we could not provide).
  • First responders and military want to know any low dose and high dose > 50 mSv (instantly).
RADTriage50-TLD card
TLD dosimeter sensor

CHIPSTRATETM , Thermo Sci., Walthum, MA

CHIPSTRATE dosimeter ring, TLD chips and powder

PULL-OUT RADTriage50-TLD WITH AN EMPTY POCKET FOR A TLD-DOSIMETER

RADTriage50-TLD pull-out card with an empty pocket

(BACK OF A RADTriage50-TLD WITHOUT A TLD-DOSIMETER)

Back of RADTriage50-TLD without a TLD dosimeter

PULL-OUT RADTriage50-TLD WITH A TLD-DOSIMETER PARTIALLY IN THE POCKET

RADTriage50-TLD with TLD dosimeter partially in the pocket

PULL-OUT RADTriage50-TLD WITH TLD-DOSIMETER PULLED-OUT FOR READING DOSE AFTER RADIATION

RADTriage50-TLD with TLD dosimeter pulled out for reading

CHIPSTRATE® DOSIMETERS AND A HOLDER FOR READING THE DOSE WITH A TLD READER

CHIPSTRATE dosimeters and holder
Holder with CHIPSTRATE dosimeters

A TLD READER (MODEL 4500) OF THERMO FOR READING DOSE OF TWO CHIPSTRATE® AT A TIME

Thermo TLD reader Model 4500

THREE PRODUCTS

  • The RADTriage card can be sold with and without the TLD-dosimeter
  • The TLD-dosimeter can be sold separately
  • Users can purchase either one of them
Three RADTriage-TLD product options

CUT-OUT RADTriage-TLD (SINGLE USE)

Cut-out RADTriage-TLD single-use card

RADTriage-TLD (BACK of the card)

Back of RADTriage-TLD card

RADTriage-TLD (TLD CHIP CUT OUT)

RADTriage-TLD with TLD chip cut out

RADTriage-TLD (BACK of the card)

Back of RADTriage-TLD card with barcode and TLD cut-out

WHEN RADTriage-TLD DOSIMETERS ARE NEEDED?

  • RADTriage should be stockpiled and needed during the first months of radiological emergency.
  • RADTriage Cut-out TLD can be used/carried by first responders and military. If a radiological incident occurs, they return for reading the dose.
  • RADTriage Pull-out TLD is needed post radiological incident. After the incident governments wants to measure dose of children, pregnant women and people living in affected area to measure the dose with TLD on routine basis (e.g., every month or three months) and calm the public that they are not exposed to high dose with RADTriage. (Fukushima area needed but we could not provide)
Cut-out RADTriage-TLD card
RADTriage-TLD pull-out card
RADTriage-TLD card

A PROTOTYPE RADTriage-TLD READER

A prototype TLD reader developed by JP Labs.

It weighs ~3kg, can be operated on a battery as
well, takes 30 seconds to read the dose.

Prototype RADTriage-TLD reader

We have made and we have capability of making RADTriage-TLD/OSL but we don’t manufacture them now unless the order is large.